Fluent:2D圓柱軸對(duì)稱模型的不收斂錯(cuò)誤處理

2016-09-25  by:CAE仿真在線  來(lái)源:互聯(lián)網(wǎng)

情況1:

話說(shuō)上節(jié)千辛萬(wàn)苦的設(shè)置好了運(yùn)行環(huán)境,沒(méi)想到不到一秒,軟件就說(shuō)有無(wú)法收斂的錯(cuò)誤,運(yùn)行不了,到底是怎么回事呢?仔細(xì)看下了一下軟件報(bào)錯(cuò)的兩個(gè)問(wèn)題:

1. 請(qǐng)?jiān)谥行木€設(shè)置軸的邊界條件。

2. X-momentum AMG求解器中無(wú)法收斂。

對(duì)于第一個(gè)警告,無(wú)法理解,明明是設(shè)置了Axis的邊界條件,為什么還會(huì)出現(xiàn)這個(gè)問(wèn)題,沒(méi)辦法,上網(wǎng)Google第二個(gè)錯(cuò)誤吧,終于發(fā)現(xiàn)了一位大神的提醒:One reason could be that the geometry is not correct. Do a Mesh->Check to make sure you don't get
Checking for nodes that lie below the x-axis.
WARNING: Invalid axisymmetric mesh: 6 nodes lie below the x-axis.
and
WARNING: Mesh check failed.
For axisymmetric, the axial direction should be x and radial is positive y. Even if the y starts with -1e-32, it will fail.
To fix this:
Use Mesh->Translate and move the geometry so ymin is +ve.

原來(lái)對(duì)于軸對(duì)稱零件,軸的方向必須是x軸,我之前并沒(méi)有檢查這個(gè),是不是這個(gè)原因呢,趕緊用Pro/E在建一個(gè)模型,這次將長(zhǎng)邊設(shè)在x軸上。

Fluent13實(shí)戰(zhàn)一:2D圓柱的定常流動(dòng)(Troubleshooting篇)
其他設(shè)置條件不變,再跑一遍,耶,成功!128次的時(shí)候收斂~


Fluent13實(shí)戰(zhàn)一:2D圓柱的定常流動(dòng)(Troubleshooting篇)

結(jié)果分析:


1. 將入口改為mass-flow-inlet,并設(shè)定質(zhì)量流量為0.138kg/s,相當(dāng)于2.2gpm,運(yùn)行模擬得到速度云圖

Fluent13實(shí)戰(zhàn)一:2D圓柱的定常流動(dòng)(Troubleshooting篇)


Fluent13實(shí)戰(zhàn)一:2D圓柱的定常流動(dòng)(Troubleshooting篇)


可以看到在層流情況下,越往外流速最慢,最外面一層速度為0,這個(gè)是符合層流的特點(diǎn)的;中間水流速為0.11m/s,這和水流速公式計(jì)算結(jié)果是一致的(v=Q/S= 8.3x10-3/(60*3.14159*0.02^2)=0.11)


情況2:

還有一種情況:

Divergence detected in AMG solver: pressure correction
Divergence detected in AMG solver: vof-1
Divergence detected in AMG solver: pressure correction
Divergence detected in AMG solver: vof-1
Divergence detected in AMG solver: pressure correction
Divergence detected in AMG solver: vof-1
Divergence detected in AMG solver: pressure correction
Divergence detected in AMG solver: vof-1
Error at host: floating point exception

 The total mass flow at degassing BC is -1.#IND00e+00 (kg/s)


Error at Node 0: floating point exception

Error at Node 1: floating point exception

Error at Node 2: floating point exception

Error at Node 3: floating point exception

Error: floating point exception
Error Object: #f

這是fluent16采用軸對(duì)稱、歐拉多相流、使用degassing出口的情況

由于planar是可以正常計(jì)算的,根據(jù)提示第一感覺這個(gè)錯(cuò)誤看似是軸對(duì)稱與degassing不兼容的問(wèn)題造成,實(shí)際上不是

那問(wèn)題是不是仍然是對(duì)稱區(qū)域不在y+x+的問(wèn)題呢?


果然是這樣!

解決辦法是在ansys workbench 的designmodeler中選擇2d平面的所有草圖線段,然后使用move方法,可以往y+x+方向隨便移動(dòng)一個(gè)距離即可



情況3:如果是旋轉(zhuǎn)對(duì)稱怎么辦呢?

有人說(shuō)只能以x軸來(lái)做對(duì)稱軸,這個(gè)讀者請(qǐng)自己去驗(yàn)證。




 


開放分享:優(yōu)質(zhì)有限元技術(shù)文章,助你自學(xué)成才

相關(guān)標(biāo)簽搜索:Fluent:2D圓柱軸對(duì)稱模型的不收斂錯(cuò)誤處理 Fluent培訓(xùn) Fluent流體培訓(xùn) Fluent軟件培訓(xùn) fluent技術(shù)教程 fluent在線視頻教程 fluent資料下載 fluent分析理論 fluent化學(xué)反應(yīng) fluent軟件下載 UDF編程代做 Fluent、CFX流體分析 HFSS電磁分析 

編輯
在線報(bào)名:
  • 客服在線請(qǐng)直接聯(lián)系我們的客服,您也可以通過(guò)下面的方式進(jìn)行在線報(bào)名,我們會(huì)及時(shí)給您回復(fù)電話,謝謝!
驗(yàn)證碼

全國(guó)服務(wù)熱線

1358-032-9919

廣州公司:
廣州市環(huán)市中路306號(hào)金鷹大廈3800
電話:13580329919
          135-8032-9919
培訓(xùn)QQ咨詢:點(diǎn)擊咨詢 點(diǎn)擊咨詢
項(xiàng)目QQ咨詢:點(diǎn)擊咨詢
email:kf@1cae.com